Display-equipped gas detector family for ATEX Zone 2 applications, with magnetic calibration, 4–20 mA signalling and relay outputs. Sensor and gas range depend on the ordered variant.

Technical documents ↓
ManufacturerSensitron
Model / familySMART 3G D3
SystemGas detection
Selection & quotationBased on project specification, configuration and quantities.

Technical specifications

Operating voltage12-24 VdcSource · 2 ↗
OutputsAnalogue 4-20 mA output; 3 relays; serial RS485 output (optional)Source · 2 ↗
IP ratingIP65 (with dust adapter)Source · 3 ↗
Weight1210 gSource · 3 ↗
Application — CatalyticIndustrial area, ATEX Zone 2 and Zone 22 (when equipped with dust adapter, optional)Source · 2 ↗
Application — ElectrochemicalIndustrial area, ATEX Zone 2 and Zone 22 (when equipped with dust adapter, optional)Source · 2 ↗
Application — InfraredIndustrial area, ATEX Zone 2 e Zone 22 (equipped with dust adapter, optional)Source · 2 ↗
Application — PIDIndustrial area, ATEX Zone 2 e Zone 22 (when equipped with dust adapter, optional)Source · 2 ↗
Detection principle — CatalyticCatalyticSource · 2 ↗
Detection principle — ElectrochemicalElectrochemical cellSource · 2 ↗
Detection principle — InfraredInfraredSource · 2 ↗
Detection principle — PIDPhotoionizator (PID)Source · 2 ↗
Detectable gases — CatalyticMethane, LPG, Propane, Butane, Petrol VapoursSource · 2 ↗
Detectable gases — ElectrochemicalO2 [0-25% Vol], CO [0-500/1000 ppm], NH3 [0-100/200/1000/5000 ppm], H2S [0- 50/100 ppm], NO [0 - 100 ppm]; H2 [0 - 2000/3000 ppm]Source · 2 ↗
Detectable gases — InfraredFlammable, refrigerant and CO2Source · 2 ↗
Detectable gases — PIDVolatile Organic Compounds (VOC) having photoionization potential up to 10.6 eVSource · 2 ↗
Measurement range — Catalytic0 - 100% LFLSource · 2 ↗
Measurement range — Infrared0 - 100% LFL flammable gas 0 - 2000 ppm refrigerant gas 0-2%Vol; 0-5%Vol; 0-30%Vol; 0-100%Vol CO2Source · 2 ↗
Measurement range — PID0 - 20 ppm (Isobutylene) 0 - 200 ppm (Isobutylene) 0 - 2000 ppm (Isobutylene)Source · 2 ↗
Maximum power consumption5.4 WSource · 2 ↗
Relay contact ratings1.0 A at 24 VdcSource · 2 ↗
Display and indication7-segment display, 5 status LED and 4 intelligent LEDSource · 2 ↗
Storage temperature — Catalytic-40 / +85°CSource · 2 ↗
Storage temperature — Electrochemical0 / +20°C up to six monthsSource · 2 ↗
Storage temperature — Infrared-40 / +85°CSource · 2 ↗
Operating temperature — Catalytic-40 / +45°CSource · 2 ↗
Operating temperature — Electrochemical-30 / +45°CSource · 2 ↗
Operating temperature — Infrared-40 / +45°CSource · 2 ↗
Relative humidity — Catalytic0 / 90% RHSource · 2 ↗
Relative humidity — Electrochemical15 / 90% RH non condensingSource · 2 ↗
Relative humidity — Infrared0 / 90% RHSource · 2 ↗
Relative humidity — PID(non condensing)Source · 3 ↗
Housing materialEnclosure: Aluminium Sensor head: stainless steelSource · 3 ↗
Dimensions — Catalytic106 x 160 x 81 mmSource · 3 ↗
Dimensions — Electrochemical106 x 160 x 81 mmSource · 3 ↗
Dimensions — Infrared106 x 160 x 81 mmSource · 3 ↗
Dimensions — PID106 x 106 x 81 mmSource · 3 ↗

Documented system connections

Related products identified in manufacturer documentation. Check the model and configuration scope in the reference.

Ratings, approvals and compatibility apply only to the models and configurations identified in the manufacturer’s documents.

AL KWARIZMI PROJECT SUPPORTSelection · BOQ review · Technical submittals · Delivery
Manufacturer reference ↗
LET’S BUILD THE RIGHT PACKAGE

From your BOQ.
To a coordinated solution.

Share your scope, drawings and project requirements.

Talk to our sales team

More from this manufacturer

WhatsAppChat on WhatsApp