SMART 3G C2
Sensitron / Gas detection

SMART 3G C2

Industrial gas detector family for ATEX Zone 1, with 4–20 mA signalling and optional relay or RS485 interfaces. Catalytic, electrochemical, infrared and PID versions are selected for the target gas.

Technical documents ↓
ManufacturerSensitron
Model / familySMART 3G C2
SystemGas detection
Selection & quotationBased on project specification, configuration and quantities.

Technical specifications

Operating voltage12-24 VdcSource · 3 ↗
OutputsAnalogue 4-20 mA output; 1 or 3 relay board (optional); serial RS485 output (optional)Source · 3 ↗
IP ratingIP65Source · 3 ↗
Application — CatalyticIndustrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)Source · 2 ↗
Application — ElectrochemicalIndustrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)Source · 2 ↗
Application — Intrinsically safe ECIndustrial area, ATEX Zone 1 and Zone 21 (when equipped with dust adapter, optional)Source · 2 ↗
Application — InfraredIndustrial area, ATEX Zone 1 e Zone 21 (when equipped with dust adapter, optional)Source · 2 ↗
Application — PIDIndustrial area, ATEX Zone 1 e Zone 21 (when equipped with dust adapter, optional)Source · 2 ↗
Detection principle — CatalyticCatalyticSource · 2 ↗
Detection principle — ElectrochemicalElectrochemical cellSource · 2 ↗
Detection principle — Intrinsically safe ECElectrochemical cellSource · 2 ↗
Detection principle — InfraredInfraredSource · 2 ↗
Detection principle — PIDPhotoionizator (PID)Source · 2 ↗
Detectable gases — CatalyticFlammable gasSource · 2 ↗
Detectable gases — ElectrochemicalO2 [0-25% Vol], CO [0-500/1000 ppm], NH3 [0-100/200/1000/5000 ppm], H2S [0- 50/100 ppm], NO [0 - 100 ppm]; H2 [0 - 2000/3000 ppm]Source · 2 ↗
Detectable gases — Intrinsically safe ECSulphur dioxide [0-20 ppm] Nitrogen dioxide [0-20 ppm] Chlorine [0-5 ppm]; [0-20 ppm] Hydrogen cyanide [0-30 ppm]Source · 2 ↗
Detectable gases — InfraredFlammable, refrigerant and CO2Source · 2 ↗
Detectable gases — PIDVolatile Organic Compounds (VOC) having photoionization potential up to 10.6 eVSource · 2 ↗
Measurement range — Catalytic0 - 100% LFLSource · 2 ↗
Measurement range — Infrared0 - 100% LFL flammable gas 0 - 2000 ppm refrigerant gas 0-2%Vol; 0-5%Vol; 0-30%Vol; 0-100%Vol CO2Source · 2 ↗
Measurement range — PID0 - 20 ppm (Isobutylene) 0 - 200 ppm (Isobutylene) 0 - 2000 ppm (Isobutylene)Source · 2 ↗
Housing material — CatalyticEnclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant Sensor head: stainless steelSource · 3 ↗
Housing material — ElectrochemicalEnclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant Sensor head: stainless steelSource · 3 ↗
Housing material — Intrinsically safe ECEnclosure: aluminium with epoxy paint chromating and chemically resistant Sensor head: stainless steelSource · 3 ↗
Housing material — InfraredEnclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant Sensor head: stainless steelSource · 3 ↗
Housing material — PIDEnclosure: aluminium pressure die-casting with epoxy paint chromating and chemically resistant Sensor head: stainless steelSource · 3 ↗
Dimensions — CatalyticWith type head 2: 120 x 162 x 90 mm With type head 3: 120 x 184 x 90 mmSource · 3 ↗
Dimensions — Electrochemical120 x 184 x 90 mmSource · 3 ↗
Dimensions — Intrinsically safe EC138 x 200 x 119 mmSource · 3 ↗
Dimensions — Infrared120 x 184 x 90 mmSource · 3 ↗
Dimensions — PID120 x 184 x 90 mmSource · 3 ↗
Weight — CatalyticWith type head 2: 1050 g With type head 3: 1250 gSource · 3 ↗
Weight — Electrochemical1250 gSource · 3 ↗
Weight — Intrinsically safe EC2700 gSource · 3 ↗
Weight — Infrared1250 gSource · 3 ↗
Weight — PID1250 gSource · 3 ↗
Storage temperature — Catalytic-40 / +85°CSource · 3 ↗
Storage temperature — Electrochemical0 / +20°C up to 6 monthsSource · 3 ↗
Storage temperature — Intrinsically safe EC0 / +20°C up to 6 monthsSource · 3 ↗
Storage temperature — Infrared-40 / +85°CSource · 3 ↗
Operating temperature — Catalytic-40 / +60°C * with type head 3 -20 / +60°C * with type head 2 codes with -HT have Tmax=70°CSource · 3 ↗
Operating temperature — Electrochemical-30 / +55°CSource · 3 ↗
Operating temperature — Intrinsically safe EC-20 / +50°CSource · 3 ↗
Operating temperature — Infrared-40 / +60°C *Source · 3 ↗
Relative humidity — Catalytic20 / 90% RH @40°C *Source · 3 ↗
Relative humidity — Electrochemical15 / 90% RH non condensingSource · 3 ↗
Relative humidity — Intrinsically safe EC15 / 90% RH non condensingSource · 3 ↗
Relative humidity — Infrared20 / 90% RH @40°C *Source · 3 ↗
Relative humidity — PID(non condensing)Source · 3 ↗
Maximum power consumption — Catalytic5.4 WSource · 3 ↗
Maximum power consumption — Electrochemical5.4 WSource · 2 ↗
Maximum power consumption — Intrinsically safe EC4.5 WSource · 3 ↗
Maximum power consumption — Infrared5.4 WSource · 3 ↗
Maximum power consumption — PID5.4 WSource · 3 ↗

Documented system connections

Related products identified in manufacturer documentation. Check the model and configuration scope in the reference.

Ratings, approvals and compatibility apply only to the models and configurations identified in the manufacturer’s documents.